BOLIY Pro3600Si/E Bedienungshandbuch

Stöbern Sie online oder laden Sie Bedienungshandbuch nach Stromgeneratoren BOLIY Pro3600Si/E herunter. BOLIY Pro3600Si/E Owner`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - The New 400 watt turbine!

The New 400 watt turbine! Owner’s Manual Wind Turbine Serial Number ___________________________________

Seite 2

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 10 AWG SIZE 14 12 10 8 6 4 3 2 1 0 2/0 3/0 4/0 X-Section Area [in2] 0.0

Seite 3

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 11 Wiring Compensation for Average Wind Speed For different average wind

Seite 4 - New Features of the AIR-X

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 12 Delta manufactures surge arrestors for lightning protection, such as t

Seite 5 - Table of Contents

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 13 If you need a code compliant switch and the voltage of your turbine is

Seite 6 - 1.2 Electrical Hazards

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 14 Choose the appropriate suggested wiring diagram below for proper wiri

Seite 7 - 1.4 Operation

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 15 B. Single AIR-X Wiring (UL Recommended Configuration) User PowerCenter

Seite 8 - 2. PACKAGE CONTENTS

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 16 C. AIR-X In a System With Solar Panels (Hybrid System) User Power C

Seite 9 - 3.1.1 Electrical Connections

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 17 D. Multiple AIR Installation AIR W ind TurbineGeneratorAIR W ind Turbi

Seite 10

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 18 NOTE: Do NOT accidentally connect the turbine “backwards” to the batt

Seite 11

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 19 3.3 Hub And Rotor Assembly Before assembling the hub and rotor refer

Seite 12 - 3.1.5 Stop Switch

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 2 NOTICES: • This information is believed to be reliable; however, S

Seite 13 - 3.1.6 System Wiring Diagrams

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 20 Please note that over-torque of blades may cause damage to the blade a

Seite 14 - A. Single AIR-X Wiring

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 21 CAUTION: IF THE WIRES ARE HOOKED-UP BACKWARDS YOU WILL DAMAGE THE AIR

Seite 15 - Figure 3-A

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 22 4. TESTING 4.1 General Discussion of Operation The available energ

Seite 16

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 23 4.1.3 Over-speed Protection All wind turbines must have some form of o

Seite 17 - Ground Rod

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 24 In regulation mode, the AIR-X controller will blink the LED 10 times e

Seite 18 - 3.2.1 Attaching to Pole

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 25 2. Below 500 RPM, the rotor should spin freely and the LED should rem

Seite 19 - Adjustment

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 26 AIR-X Adjustable Voltage Range 12v 13.6v to 17.0v preset to 14.

Seite 20

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 27 An important fact to keep in mind is elevation. The higher a wind gen

Seite 21

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 28 6. WARRANTY POLICY What Is Covered And For How Long For turbines that

Seite 22 - 4. TESTING

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 29 7. SPECIFICATIONS 7.1 TECHNICAL SPECIFICATIONS Rotor Diameter: 46

Seite 23

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 3 CONGRATULATIONS! You have just purchased the most advanced battery ch

Seite 24 - 4.2 Bench Testing

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 30 7.2 PERFORMANCE SPECIFICATIONS The following curve shows the performan

Seite 25 - 4.3 Performance Test

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 31 7.3 Sphere of Operation 7.4 Exploded View of AIR-X

Seite 26 - 5.3 Elevation

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 32 8. MAINTENANCE Although your AIR-X has been designed to run for long

Seite 27

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 33 Flooded Lead Acid, Wet Lead Acid or flooded lead-acid batteries are t

Seite 28

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 34 9.2 Regulator Options The internal electronics protect you and your ba

Seite 29 - 7.1 TECHNICAL SPECIFICATIONS

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 35 for extended periods of time. Most solar controllers will open the sol

Seite 30 - AIR-X Monthly Energy Output

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 36 Figure 9

Seite 31 - 7.4 Exploded View of AIR-X

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 37 11. TOWERS There are a few things to consider when choosing the corre

Seite 32

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 38 Basic aerodynamics show that as wind moves over or around objects, the

Seite 33

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 39 12. FREQUENTLY ASKED QUESTIONS These frequently asked questions are s

Seite 34 - 9.2 Regulator Options

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 4 New Features of the AIR-X The AIR-X is the latest evolution of the A

Seite 35 - 10. SITING

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 40 The microprocessor in the AIR-X constantly monitors turbine RPM, and i

Seite 36

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 41 batteries BEFORE being connected to negative. It is important that yo

Seite 37

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 42 are used. If your turbines are at various distances from the batterie

Seite 38

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 43 output power drops off to about 75 watts. The wiring could be sized f

Seite 39

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 44 in amp-hours and have some indication of the number of charge-discharg

Seite 40 - Installation

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 45 to you. They may be available at an automotive parts store. Otherwise

Seite 41

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 46 Guyed tower Kits We offer 27’ (8.2 m) and 45’ (13.7 m) guyed towers.

Seite 42

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 47 14. REFERENCES Wind Energy The Wind Power Book J. Park Hackleman

Seite 43

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 48 Lightning Protection Lightning Protection R.H. Golde Chemical Pu

Seite 44

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 5 Table of Contents 1. Safety Precautions……………………………………………………….

Seite 45

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 6 1. SAFETY PRECAUTIONS The AIR-X has been designed with your safety in

Seite 46

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 7 1.3 Installation CAUTION: INSTALLATION PROCEDURES SHOULD BE PERFORMED

Seite 47 - 14. REFERENCES

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 8 2. PACKAGE CONTENTS Compare the parts shown in Figure 1 to ensure that

Seite 48

AIR-X Land Manual Document #0056 REV D SOUTHWEST WINDPOWER 10/09/2002 9 3. WIRING AND INSTALLATION PROCEDURES Your AIR-X is shipped partially